Silicon Nitride AFM Probes

Silicon Nitride AFM Probes

Silicon nitride XNC12 triangular AFM cantilevers

Typical radius of uncoated AFM tip
10nm
Resulting AFM tip radius with the coating
30nm
Full AFM tip cone angle
70°
Total AFM tip height
3.5nm
AFM Probe material
Silicon nitride
AFM Tip coating
None or Gold
Detector coating
Gold

The XNC12 series AFM probes have 2 different triangular silicon nitride AFM cantilevers on one side of the holder chip. The AFM cantilevers are thin and soft. Each AFM cantilever has a square pyramidal silicon nitride AFM tip with a sharpened apex. Silicon nitride AFM probes are manufactured using thin film technology. As a result, their AFM cantilevers can be thinner and with lower force constants than those made of silicon. In addition, silicon nitride is harder than silicon, offering good AFM tip durability.

The AFM probes have a 70nm thick gold coating on the back side of the AFM cantilever that enhances laser reflectivity. Two options are available for the tip side of the AFM cantilevers: no coating or a 35nm thick gold coating.


2 AFM Cantilevers Series

AFM Cantilever Resonance Frequency, kHz Force Constant, N/m
min typical max min typical max
12 series Cantilever A   17     0.08  
Cantilever B   67     0.32  


Application

Silicon nitride AFM probes are often used for soft contact mode measurements on biological samples and other soft matter. The reflective gold coating is chemically inert and ensures stable reflectivity in liquids and buffer solutions. The optional tip side gold coating makes the AFM tip slightly rounder and more suitable for scanning extremely sensitive and tear prone surfaces such as cell membranes. It also opens the possibility for AFM tip functionalization.

The XNC12 AFM probes are intended for contact mode measurements on biological and other soft samples in air and liquids. The gold coating on the detector side of the AFM cantilever ensures strong and stable reflectivity in various gaseous and liquid ambients.

The uncoated AFM tips provide very good resolution, while the gold coated AFM tips offer extra protection when scanning very soft samples. In addition, gold coated AFM tips are suitable for tip functionalization.

AFM topography image of human erythrocytes performed with the long cantilever of the XNC12 in contact mode.



XNC12/Cr-Au BS

AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers

AFM probes of the XNC12 series have 2 silicon nitride AFM cantilevers and AFM tips on a glass holder chip. They are used for soft contact mode applications.

The gold reflective coating enhances the laser reflectivity of the AFM cantilevers.

Coating

Reflective Gold

 

AFM Probe Specifications

AFM Tip

Shape Height Full Cone Angle Radius
Pyramid 3.5 µm 40° < 10 nm

AFM Cantilever

Cantilever Shape Force Const. Res. Freq. Length Width Thickness
Cantilever A Triangle 0.08 N/m 17 kHz 200 µm(190 - 210µm) 28 µm(23 - 33µm) 500 nm(425 - 575 nm)
Cantilever B Triangle 0.32 N/m 67 kHz 100 µm(90 - 110µm) 13.5 µm(8.5 - 18.5µm) 500 nm(425 - 575 nm)

All typical values


XNC12/Cr-Au

AFM Probe with Gold Coated  Silicon Nitride AFM Cantilevers

AFM probes of the XNC12 series have 2 silicon nitride AFM cantilevers and AFM tips on a glass holder chip. They are used for soft contact mode applications.

The overall gold coating with 20 nm chromium sublayer is electrically conductive and chemically inert. It also ehnances the laser reflectivity of the AFM cantilevers. The coating may cause AFM cantilever bending up to 3°

Coating

Gold Overall

 

AFM Probe Specifications

AFM Tip

Shape Height Full Cone Angle Radius
Pyramid 3.5 µm 40° < 10 nm

AFM Cantilever

Cantilever Shape Force Const. Res. Freq. Length Width Thickness
Cantilever A Triangle 0.08 N/m 17 kHz 200 µm(190 - 210µm) 28 µm(23 - 33µm) 500 nm(425 - 575 nm)
Cantilever B Triangle 0.32 N/m 67 kHz 100 µm(90 - 110µm) 13.5 µm(8.5 - 18.5µm) 500 nm(425 - 575 nm)

All typical values

Documentation

🚚 Estimated Delivery: 5 - 6 weeks from payment confirmation

View full details
Your cart
Variant Variant total Quantity Price Variant total
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/10 (Unit: each)XNC12/Cr-Au BS-10
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/10 (Unit: each)XNC12/Cr-Au BS-10
1.404,38 lei/ea
0,00 lei
1.404,38 lei/ea 0,00 lei
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/35 (Unit: each)XNC12/Cr-Au BS-35
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/35 (Unit: each)XNC12/Cr-Au BS-35
4.156,95 lei/ea
0,00 lei
4.156,95 lei/ea 0,00 lei
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/70 (Unit: each)XNC12/Cr-Au BS-70
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/70 (Unit: each)XNC12/Cr-Au BS-70
7.527,45 lei/ea
0,00 lei
7.527,45 lei/ea 0,00 lei
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/10 (Unit: each)XNC12/Cr-Au-10
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/10 (Unit: each)XNC12/Cr-Au-10
1.657,16 lei/ea
0,00 lei
1.657,16 lei/ea 0,00 lei
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/35 (Unit: each)XNC12/Cr-Au-35
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/35 (Unit: each)XNC12/Cr-Au-35
4.887,23 lei/ea
0,00 lei
4.887,23 lei/ea 0,00 lei
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/70 (Unit: each)XNC12/Cr-Au-70
AFM Probe with Gold Coated Silicon Nitride AFM Cantilevers, pkg/70 (Unit: each)XNC12/Cr-Au-70
8.959,91 lei/ea
0,00 lei
8.959,91 lei/ea 0,00 lei

View cart
0

Total items

0,00 lei

Product subtotal

Taxes, discounts and shipping calculated at checkout.
View cart