{"product_id":"soft-tapping-mode-afm-probes-1","title":"Soft Tapping Mode AFM Probes","description":"\u003cp\u003e\u003ca href=\"https:\/\/www.budgetsensors.com\/\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/BS-logo.png?v=1779784298\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"BudgetSensors Tap150 Series AFM Probes\" src=\"https:\/\/www.youtube.com\/embed\/KrgW8HuTM-s\" height=\"524\" width=\"917\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eTap150-G\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eSoft Tapping Mode AFM Probe\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eAFM Probe Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"techData tips clearfix\"\u003e\n\u003ch3\u003eAFM Tip\u003c\/h3\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eShape:\u003c\/strong\u003e Rotated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17 µm \u003cspan class=\"light\"\u003e(15 - 19 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eSetback:\u003c\/strong\u003e 15 µm \u003cspan class=\"light\"\u003e(10 - 20 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eRadius:\u003c\/strong\u003e \u0026lt; 10 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-4\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHalf Cone Angle:\u003c\/strong\u003e 20°-25° along cantilever axis, 25°-30° from side, 10° at the apex\u003c\/div\u003e\n\u003cdiv class=\"spec\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cantilevers\"\u003e\n\u003ch3\u003eAFM Cantilever\u003c\/h3\u003e\n\u003cdiv class=\"techData  col-lg-12 pl0 clearfix\" id=\"cantilever1\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cdiv class=\"cantilever\"\u003eCantilever A\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eShape:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeam\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eForce Constant:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  5 N\/m (1.5 - 15 N\/m)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eResonance Frequency:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 150 kHz (75 - 225 kHz)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eLength:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125 µm\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"light\"\u003e(115 - 135 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eWidth:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 25 µm (20 - 30 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eThickness:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  2.1 µm (1.1 - 3.1 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e* typical range\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"probe_coating clearfix\"\u003e\n\u003ch3\u003eCoating\u003c\/h3\u003e\n\u003cp\u003eUncoated\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAlignment Grooves\u003c\/h3\u003e\n\u003cp\u003eThis product features alignment grooves on the back side of the holder chip.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a19788d7be80dcdfd27d5fd7590eee5f5ee3bde4.png?v=1779898973\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d2b21d245ae46545b9615e67bb20d16afd5574de.png?v=1779898999\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d559d8a3ba0714bc73e4434b1a8387ce2e2fdde4.png?v=1779899025\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAdditional Info\u003c\/h3\u003e\n\u003cp\u003eMonolithic silicon AFM probe for soft tapping mode operation.\u003c\/p\u003e\n\u003cp\u003eThe rotated AFM tip allows for more symmetric representation of high sample features. The consistent AFM tip radius ensures good resolution and reproducibility.\u003c\/p\u003e\n\u003cp\u003eThe AFM holder chip fits most commercial AFM systems as it is industry standard size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor measurements in liquids please use the back side gold coated\u003cspan\u003e \u003c\/span\u003eTap150GD-G\u003cspan\u003e \u003c\/span\u003eor the overall gold coated\u003cspan\u003e \u003c\/span\u003eTap150GB-G!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsistent high quality at a lower price!\u003c\/p\u003e\n\u003chr\u003e\u003chr\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eTap150Al-G\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan\u003eSoft Tapping Mode AFM Probe with Aluminum Reflective Coating\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eAFM Probe Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"techData tips clearfix\"\u003e\n\u003ch3\u003eAFM Tip\u003c\/h3\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eShape:\u003c\/strong\u003e Rotated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17 µm \u003cspan class=\"light\"\u003e(15 - 19 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eSetback:\u003c\/strong\u003e 15 µm \u003cspan class=\"light\"\u003e(10 - 20 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eRadius:\u003c\/strong\u003e \u0026lt; 10 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-4\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHalf Cone Angle:\u003c\/strong\u003e 20°-25° along cantilever axis, 25°-30° from side, 10° at the apex\u003c\/div\u003e\n\u003cdiv class=\"spec\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cantilevers\"\u003e\n\u003ch3\u003eAFM Cantilever\u003c\/h3\u003e\n\u003cdiv class=\"techData  col-lg-12 pl0 clearfix\" id=\"cantilever1\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cdiv class=\"cantilever\"\u003eCantilever A\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eShape:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeam\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eForce Constant:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  5 N\/m (1.5 - 15 N\/m)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eResonance Frequency:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 150 kHz (75 - 225 kHz)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eLength:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125 µm\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"light\"\u003e(115 - 135 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eWidth:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 25 µm (20 - 30 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eThickness:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  2.1 µm (1.1 - 3.1 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e* typical range\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"probe_coating clearfix\"\u003e\n\u003ch3\u003eCoating\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAluminium reflex coating on detector side of the cantilever, 30 nm thick\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAlignment Grooves\u003c\/h3\u003e\n\u003cp\u003eThis product features alignment grooves on the back side of the holder chip.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a19788d7be80dcdfd27d5fd7590eee5f5ee3bde4.png?v=1779898973\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d2b21d245ae46545b9615e67bb20d16afd5574de.png?v=1779898999\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d559d8a3ba0714bc73e4434b1a8387ce2e2fdde4.png?v=1779899025\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAdditional Info\u003c\/h3\u003e\n\u003cp\u003eMonolithic silicon AFM probe for soft tapping mode operation.\u003c\/p\u003e\n\u003cp\u003eThe rotated AFM tip allows for more symmetric representation of high sample features. The consistent AFM tip radius ensures good resolution and reproducibility.\u003c\/p\u003e\n\u003cp\u003eThe AFM holder chip fits most commercial AFM systems as it is industry standard size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor measurements in liquids please use the back side gold coated\u003cspan\u003e \u003c\/span\u003eTap150GD-G\u003cspan\u003e \u003c\/span\u003eor the overall gold coated\u003cspan\u003e \u003c\/span\u003eTap150GB-G!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsistent high quality at a lower price!\u003c\/p\u003e\n\u003chr\u003e\u003chr\u003e\n\u003cp\u003e\u003ciframe title=\"BudgetSensors Gold Series AFM Probes\" src=\"https:\/\/www.youtube.com\/embed\/ymey_oRf9n0\" height=\"524\" width=\"917\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eTap150Al-G\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cspan\u003eSoft Tapping Mode AFM Probe with Gold Reflective Coating\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eAFM Probe Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"techData tips clearfix\"\u003e\n\u003ch3\u003eAFM Tip\u003c\/h3\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eShape:\u003c\/strong\u003e Rotated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17 µm \u003cspan class=\"light\"\u003e(15 - 19 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eSetback:\u003c\/strong\u003e 15 µm \u003cspan class=\"light\"\u003e(10 - 20 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eRadius:\u003c\/strong\u003e \u0026lt; 10 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-4\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHalf Cone Angle:\u003c\/strong\u003e 20°-25° along cantilever axis, 25°-30° from side, 10° at the apex\u003c\/div\u003e\n\u003cdiv class=\"spec\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cantilevers\"\u003e\n\u003ch3\u003eAFM Cantilever\u003c\/h3\u003e\n\u003cdiv class=\"techData  col-lg-12 pl0 clearfix\" id=\"cantilever1\" xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\"\u003e\n\u003cdiv class=\"cantilever\"\u003eCantilever A\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eShape:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeam\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eForce Constant:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  5 N\/m (1.5 - 15 N\/m)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eResonance Frequency:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 150 kHz (75 - 225 kHz)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eLength:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e125 µm\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"light\"\u003e(115 - 135 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eWidth:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 25 µm (20 - 30 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eThickness:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  2.1 µm (1.1 - 3.1 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e* typical range\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"probe_coating clearfix\"\u003e\n\u003ch3\u003eCoating\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eGold coating on detector side of the cantilever, 70 nm thick\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAlignment Grooves\u003c\/h3\u003e\n\u003cp\u003eThis product features alignment grooves on the back side of the holder chip.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a19788d7be80dcdfd27d5fd7590eee5f5ee3bde4.png?v=1779898973\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d2b21d245ae46545b9615e67bb20d16afd5574de.png?v=1779898999\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d559d8a3ba0714bc73e4434b1a8387ce2e2fdde4.png?v=1779899025\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAdditional Info\u003c\/h3\u003e\n\u003cp\u003eMonolithic silicon AFM probe for soft tapping mode operation.\u003c\/p\u003e\n\u003cp\u003eThe rotated AFM tip allows for more symmetric representation of high sample features. The consistent AFM tip radius ensures good resolution and reproducibility.\u003c\/p\u003e\n\u003cp\u003eThe AFM holder chip fits most commercial AFM systems as it is industry standard size.\u003c\/p\u003e\n\u003cp\u003eConsistent high quality at a lower price!\u003c\/p\u003e","brand":"BudgetSensors","offers":[{"title":"TAP150-G AFM Probe for Soft Tapping Mode, uncoated, alignment grooves (Unit: pkg\/10)","offer_id":56662005055814,"sku":"Tap150-G-10","price":1101.44,"currency_code":"RON","in_stock":true},{"title":"TAP150-G AFM Probe for Soft Tapping Mode, uncoated, alignment grooves (Unit: pkg\/50)","offer_id":56677022531910,"sku":"Tap150-G-50","price":4829.38,"currency_code":"RON","in_stock":true},{"title":"TAP150-G AFM Probe for Soft Tapping Mode, uncoated, alignment grooves (Unit: pkg\/380)","offer_id":56677032264006,"sku":"Tap150-G-380","price":25417.8,"currency_code":"RON","in_stock":true},{"title":"TAP150Al-G AFM Probe for Soft Tapping Mode, Al reflex coating, alignment grooves (Unit: pkg\/10)","offer_id":56677045502278,"sku":"Tap150Al-G-10","price":1157.92,"currency_code":"RON","in_stock":true},{"title":"TAP150Al-G AFM Probe for Soft Tapping Mode, Al reflex coating, alignment grooves (Unit: pkg\/50)","offer_id":56677046780230,"sku":"Tap150Al-G-50","price":5055.32,"currency_code":"RON","in_stock":true},{"title":"TAP150Al-G AFM Probe for Soft Tapping Mode, Al reflex coating, alignment grooves (Unit: pkg\/380)","offer_id":56677047238982,"sku":"Tap150Al-G-380","price":25417.8,"currency_code":"RON","in_stock":true},{"title":"TAP150Al-G AFM Probe for Soft Tapping Mode, Au reflex coating, alignment grooves (Unit: pkg\/10)","offer_id":56677053169990,"sku":"Tap150GD-G-10","price":1468.58,"currency_code":"RON","in_stock":true},{"title":"TAP150Al-G AFM Probe for Soft Tapping Mode, Au reflex coating, alignment grooves (Unit: pkg\/50)","offer_id":56677053890886,"sku":"Tap150GD-G-50","price":6100.27,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a19788d7be80dcdfd27d5fd7590eee5f5ee3bde4.png?v=1779898973","url":"https:\/\/allemee.com\/products\/soft-tapping-mode-afm-probes-1","provider":"AllEm","version":"1.0","type":"link"}