{"product_id":"scanasyst®-afm-probes","title":"ScanAsyst®* AFM Probes","description":"\u003ch2 class=\"Polaris-Header-Title\" tabindex=\"-1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/MikroMasch-Logo.svg?v=1768988367\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/f8e62cf2ddc9c8cb25a7618cd7e21e9993776c1b.jpg?v=1769618353\" alt=\"\" width=\"227\" height=\"175\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003eSelfAdjust-Air AFM cantilever close-up\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/2f490b9101124bc947a5dbca3a9dd3a9d3de9a00.jpg?v=1769618399\" alt=\"\" width=\"310\" height=\"225\"\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cem\u003eSelfAdjust-Air AFM tip close-up\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca href=\"\/pages\/scanasyst%C2%AE-mode-afm-using-mikromasch%C2%AE-selfadjust-air-afm-probes\"\u003e\u003cem\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/How_to_Use_SelfAdjust-Air_on_Bruker_AFM.jpg?v=1769618522\" alt=\"\"\u003e\u003c\/em\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"MikroMasch HQ Line NSC18 \u0026amp; NSC19 AFM Probes\" src=\"https:\/\/www.youtube.com\/embed\/hHvmbh7WCt4\" height=\"535\" width=\"936\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eTypical AFM tip radius\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e2nm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eMaximum AFM tip radius\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e8nm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eFull cone angle\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e40°\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eTotal AFM tip height\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNom: 5µm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRange: 4-7µm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eEffective AFM tip height\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eNom: 2.5µm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRange: 2-3.5µm\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eAFM tip material\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003en-type silicon\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eAFM cantilever material\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSilicon-based amorphous thin layer\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eDetector coating\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAluminum\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe SelfAdjust-Air AFM cantilevers feature finely tuned properties, optimal for ScanAsyst®* mode operation.\u003c\/p\u003e\n\u003cp\u003eThe silicon AFM tips have trihedral shape and the sharpest silicon apexes in our entire product range with typical radius of curvature 2nm and maximum radius of curvature below 8nm. The full AFM tip cone angle is 40° and even lower at the last 200nm near the AFM tip apex.\u003c\/p\u003e\n\u003cp\u003eThe aluminum reflective coating enhances the laser reflectivity of the AFM cantilever by approximately 2.5 times.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWe recommend using SelfAdjust-Air AFM tips for measurements in ScanAsyst® PeakForce Tapping™* mode. Alternatively, the soft tapping mode HQ:NSC19\/Al BS AFM tips can be used and some customers even prefer them for measurements in ScanAsyst®* mode. However, SelfAdjust-Air have been designed specifically for ScanAsyst® PeakForce Tapping™* mode application and are therefore the preferred choice. For more information on the HQ series soft tapping mode AFM tips check\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003ca href=\"\/pages\/scanasyst%C2%AE-mode-afm-using-mikromasch%C2%AE-selfadjust-air-afm-probes\"\u003ehere\u003c\/a\u003e\u003ca href=\"https:\/\/www.spmtips.com\/soft-tapping-mode-afm-probes-by-MikroMasch\"\u003e\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch5\u003e1-AFM Cantilevers Series\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.spmtips.com\/uploads\/media\/default\/0001\/08\/93fd503bd49ab6494eba31083df91014b0bfce5c.jpeg\" alt=\"\" width=\"500\" height=\"422\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"scrollable-content\"\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\"\u003e\u003cstrong\u003eAFM Cantilever\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003e\u003cstrong\u003eResonance Frequency, kHz\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003e\u003cstrong\u003eForce Constant, N\/m\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emin\u003c\/th\u003e\n\u003cth\u003etypical\u003c\/th\u003e\n\u003cth\u003emax\u003c\/th\u003e\n\u003cth\u003emin\u003c\/th\u003e\n\u003cth\u003etypical\u003c\/th\u003e\n\u003cth\u003emax\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\"\u003eSelfAdjust-Air\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e70\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e0.25\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\"\u003eHQ:NSC19\/Al BS\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e65\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eApplication\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eSelfAdjust-Air AFM tips can be used for imaging both hard samples and soft biological samples in ScanAsyst® PeakForce Tapping™* mode. The low interaction force allows preserving both the AFM tip and the sample, allowing very high resolution scans.\u003c\/p\u003e\n\u003cp\u003e\u003cimg title=\"Bruker’s Tip Qualification module is used to assess the sharpness of a SelfAdjust-Air AFM tip based on a scan of the MikroMasch PA01 AFM tip evaluation sample.\" src=\"https:\/\/www.spmtips.com\/uploads\/media\/default\/0001\/08\/876f7acd998877368dff3216faa1a0b2aaae13a7.png\" alt='\"'\u003e\u003cbr\u003e\u003cem\u003eBruker’s Tip Qualification module is used to assess the sharpness of a SelfAdjust-Air AFM tip based on a scan of the MikroMasch® PA01 AFM tip evaluation sample.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cbr\u003e\u003cimg title=\"SEBS-BH 2 µm AFM Images - MikroMasch® NSC19 Series and SelfAdjust-Air AFM Probes\" src=\"https:\/\/www.spmtips.com\/uploads\/media\/default\/0001\/08\/9ce4cc9fcee8b937dc748f599c05ab90460cf4be.jpeg\" alt=\"SEBS-BH 2 µm AFM Images - MikroMasch® NSC19 Series and SelfAdjust-Air AFM Probes\" width=\"569\" height=\"532\"\u003e\u003cbr\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSEBS-BH 2 µm AFM Images - MikroMasch® NSC19 Series and SelfAdjust-Air AFM Probes\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg title=\"OSC-Elastomer Blend 40 µm AFM Images – MikroMasch® SelfAdjust-Air AFM Probes\" src=\"https:\/\/www.spmtips.com\/uploads\/media\/default\/0001\/08\/72ff2d6c8f384494d9f6a9dc4a5c8999386870f1.jpeg\" alt=\"OSC-Elastomer Blend 40 µm AFM Images – MikroMasch® SelfAdjust-Air AFM Probes\" width=\"570\" height=\"286\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eOSC-Elastomer Blend 40 µm AFM Images – MikroMasch® SelfAdjust-Air AFM Probes\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cimg title=\"OSC-Elastomer Blend 1.5 µm AFM Images after nanomachining – MikroMasch® SelfAdjust-Air AFM Probes\" src=\"https:\/\/www.spmtips.com\/uploads\/media\/default\/0001\/08\/8469b31b7a4a2f8f813139e08dd87ced1a84ca26.jpeg\" alt=\"OSC-Elastomer Blend 1.5 µm AFM Images after nanomachining – MikroMasch® SelfAdjust-Air AFM Probes\" width=\"570\" height=\"287\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eOSC-Elastomer Blend 1.5 µm AFM Images after nanomachining – MikroMasch® SelfAdjust-Air AFM Probes\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 class=\"title title--sxl\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eSelfAdjust-Air\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eAFM probe for ScanAsyst* mode in air\u003c\/h3\u003e\n\u003cdiv class=\"content-block sbo-xs\"\u003e\n\u003cdiv class=\"text text--ul text--small\"\u003e\n\u003cp\u003eSelfAdjust-Air AFM probes are specifically designed for Bruker's ScanAsyst®* mode. The AFM cantilevers’ properties, in particular force constant and Q-factor are such that the ScanAsyst®* self-optimization algorithm is optimally supported. Bruker’s PeakForce Tapping™* mode controls and minimizes the interaction forces so precisely that the SelfAdjust-Air AFM typical tip radius of only 2nm and maximum 8nm (the sharpest silicon AFM tip in our product range!) is maintained over an extremely long period of time.\u003c\/p\u003e\n\u003cp\u003eSelfAdjust-Air AFM probes are perfectly suited for high-resolution imaging on solid surfaces and biological samples, as well as for everyday purposes for all AFM users looking for an easy-to-use AFM probe for Bruker's ScanAsyst®* mode with an outstanding lifetime.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"text text--small\"\u003e\n\u003cp\u003eReflective Aluminum\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/70kHz_0.4Nonm.jpg?v=1769667257\" alt=\"\"\u003e   \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/057b53dd4333abb1225a35499f36b1102fff8bcf.svg?v=1768991625\" alt=\"\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/227785e50b21dfbbd43641f4b0d77e7809985b92.svg?v=1769592600\" alt=\"\" width=\"41\" height=\"41\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/6f2246cc874529416ac4b333a28473694aec8947.jpg?v=1769667344\" alt=\"\" width=\"458\" height=\"316\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/7e575e456211c4bebcedd078ec6029968bfd3687.jpg?v=1769667408\" alt=\"\" width=\"244\" height=\"169\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/f8e62cf2ddc9c8cb25a7618cd7e21e9993776c1b.jpg?v=1769618353\" alt=\"\" width=\"218\" height=\"168\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/001ce649b7162d0fa59e2bbabb8001ba27dd7a6e.jpg?v=1769667497\" alt=\"\" width=\"231\" height=\"95\"\u003e     \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/cfc56b0cf90962ff9060470bbfd365921d810e8a_d82640e8-cb64-44d7-94b2-26383bce96d0.jpg?v=1769078495\" alt=\"\" width=\"214\" height=\"125\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eAFM Probe Specifications\u003c\/h3\u003e\n\u003cdiv class=\"content-block  sbo-x\"\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Tip\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eEFF Height\u003c\/th\u003e\n\u003cth\u003eFull Cone Angle\u003c\/th\u003e\n\u003cth\u003eRadius\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eRotated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e5 µm (4 - 7 µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e2.5 µm (2 - 3.5 µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e40°\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e\u0026lt; 2 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Cantilever\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCantilever\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eForce Const.\u003c\/th\u003e\n\u003cth\u003eRes. Freq.\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eThickness\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eCantilever A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eBeam\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e0.4 N\/m\u003cspan class=\"table__content-light\"\u003e(0.25 - 0.75 N\/m)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e70 kHz\u003cspan class=\"table__content-light\"\u003e(50 - 90 kHz)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e100 µm\u003cspan class=\"table__content-light\"\u003e(90 - 110µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e25 µm\u003cspan class=\"table__content-light\"\u003e(23 - 27µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e0.95 µm\u003cspan class=\"table__content-light\"\u003e(0.9 - 1 µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003eAll typical values\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 class=\"title title--sxl\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/allemee.com\/products\/soft-tapping-mode-afm-probes?_pos=1\u0026amp;_sid=a26a0323e\u0026amp;_ss=r\u0026amp;variant=55881123365190#:~:text=All%20typical%20values-,HQ%3ANSC19\/Al%20BS,-Soft%20Tapping%20Mode\"\u003eHQ:NSC19\/Al BS\u003c\/a\u003e\u003c\/span\u003e \u003cstrong\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e(click to link)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eSoft Tapping Mode and LFM AFM Probe\u003c\/h3\u003e\n\u003cp class=\"align-right gray-text\"\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 class=\"title title--sxl\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHi'Res-C19\/Cr-Au\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eHigh Resolution, Soft Tapping Mode AFM Probe\u003c\/h3\u003e\n\u003cdiv class=\"content-block sbo-xs\"\u003e\n\u003cdiv class=\"text text--ul text--small\"\u003e\n\u003cp\u003eThe high-resolution AFM probes of the Hi'Res-C series feature a hydrophobic diamond-like spike at the apex of the silicon etched AFM tip.\u003c\/p\u003e\n\u003cp\u003eAFM probes of the HQ:NSC19 series combine relatively high resonance frequency and low force constant, which makes them suitable for imaging soft and fragile surfaces at relatively high speeds in Soft tapping mode. They are compatible with Bruker ScanAsyst® PeakForce Tapping™*.\u003c\/p\u003e\n\u003cp\u003eThe HQ AFM probes offer high consistency of the AFM tip radius, the AFM cantilever reflectivity and the quality factor.\u003c\/p\u003e\n\u003cp\u003eThe overall 30 nm Au coating with 20 nm Cr sublayer is chemically inert. It also ehnances the laser reflectivity of the AFM cantilever in air and liquids. The coating does not cover the spike.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"text text--small\"\u003e\n\u003cp\u003eReflective Gold\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"43\" width=\"107\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/65kHz_0.5Nonm.jpg?v=1769592515\"\u003e   \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/62acfeecf2e7996a6e2c4069f522281ed51e7029.svg?v=1769671006\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/057b53dd4333abb1225a35499f36b1102fff8bcf.svg?v=1768991625\"\u003e \u003cimg height=\"41\" width=\"40\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/60c9f1ed8036d365045dc7162a0fcd022aaefd42.svg?v=1769066989\"\u003e \u003cimg height=\"41\" width=\"41\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/227785e50b21dfbbd43641f4b0d77e7809985b92.svg?v=1769592600\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"418\" width=\"433\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d9fe3ab77ff49cdb324489f31caaa83c19a8f204.jpg?v=1769671131\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"254\" width=\"435\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/cfc56b0cf90962ff9060470bbfd365921d810e8a.jpg?v=1769078495\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"186\" width=\"197\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/4c4b3436bf5e02821f1281931b505312cf8b86fd.jpg?v=1769595024\"\u003e \u003cimg height=\"187\" width=\"204\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/46ea892e382b1ef98e15f0ceac995a182a42ae8a.jpg?v=1769592664\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eAFM Probe Specifications\u003c\/h3\u003e\n\u003cdiv class=\"content-block  sbo-x\"\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Tip\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eRadius\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eSupersharp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e15 µm (12 - 18 µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e\u0026lt; 1 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Cantilever\u003c\/h3\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCantilever\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eForce Const.\u003c\/th\u003e\n\u003cth\u003eRes. Freq.\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eThickness\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eCantilever A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eBeam\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e0.5 N\/m\u003cspan class=\"table__content-light\"\u003e(0.05 - 2.3 N\/m)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e65 kHz\u003cspan class=\"table__content-light\"\u003e(25 - 120 kHz)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e125 µm\u003cspan class=\"table__content-light\"\u003e(120 - 130µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e22.5 µm\u003cspan class=\"table__content-light\"\u003e(19.5 - 25.5µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e1 µm\u003cspan class=\"table__content-light\"\u003e(0.5 - 1.5 µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003eAll typical values\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MikroMasch","offers":[{"title":"AFM probe for ScanAsyst* mode in air, pkg\/10 (Unit: each)","offer_id":55890441273670,"sku":"SelfAdjust-Air-10","price":1460.55,"currency_code":"RON","in_stock":true},{"title":"AFM probe for ScanAsyst* mode in air, pkg\/20 (Unit: each)","offer_id":55893480767814,"sku":"SelfAdjust-Air-20","price":2752.58,"currency_code":"RON","in_stock":true},{"title":"AFM probe for ScanAsyst* mode in air, pkg\/50 (Unit: each)","offer_id":55893491712326,"sku":"SelfAdjust-Air-50","price":6600.56,"currency_code":"RON","in_stock":true},{"title":"AFM probe for ScanAsyst* mode in air, pkg\/100 (Unit: each)","offer_id":55893510259014,"sku":"SelfAdjust-Air-100","price":12639.38,"currency_code":"RON","in_stock":true},{"title":"AFM probe for ScanAsyst* mode in air, pkg\/200 (Unit: each)","offer_id":55893514158406,"sku":"SelfAdjust-Air-200","price":23593.5,"currency_code":"RON","in_stock":true},{"title":"AFM probe for ScanAsyst* mode in air, pkg\/400 (Unit: each)","offer_id":55893515665734,"sku":"SelfAdjust-Air-400","price":42131.25,"currency_code":"RON","in_stock":true},{"title":"High Resolution, Soft Tapping Mode AFM Probe, pkg\/5 (Unit: each)","offer_id":55893585166662,"sku":"HiRes-C19\/Cr-Au-5","price":2780.66,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/7e575e456211c4bebcedd078ec6029968bfd3687.jpg?v=1769667408","url":"https:\/\/allemee.com\/products\/scanasyst%c2%ae-afm-probes","provider":"AllEm","version":"1.0","type":"link"}