{"product_id":"opus-carbon-nanofiber-afm-tips","title":"OPUS® Carbon Nanofiber AFM Tips","description":"\u003cp\u003e\u003ca href=\"https:\/\/www.spmtips.com\/\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/MikroMasch-Logo_d194e3a0-a1cc-4034-8230-132f8093c554.svg?v=1771220521\" alt=\"\" width=\"94\" height=\"51\"\u003e\u003c\/a\u003e    \u003ca href=\"https:\/\/www.opustips.com\/\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/opus-logo.svg?v=1771220408\" alt=\"\" width=\"126\" height=\"43\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"MikroMasch - OPUS Carbon Nanofiber AFM Cantilevers\" src=\"https:\/\/www.youtube.com\/embed\/jHAeAYqwb8M\" height=\"1080\" width=\"1920\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2 class=\"title title--s\"\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003e160AC-FG\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"subtitle\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eOPUS® High Aspect Ratio Standard Tapping Mode AFM Cantilever with Au Reflective Coating\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/O300kHz_26Nonm.jpg?v=1771221613\" alt=\"\" width=\"88\" height=\"46\"\u003e   \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/c54c843ac594213d1f1ff3f2f610646fbf6f7f2f.svg?v=1771221652\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/7060ef9f263008d5e11284098656c91c8e308635.svg?v=1771221709\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a780953b630073e7035e45e6bc31ed55fa166043.svg?v=1771221752\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/fe1a1af00894bcd3465a156e3506f99934c51c10.svg?v=1772198022\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a882079e57605157a188c26ef744164a1401f2ec.svg?v=1771246696\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/8d216cc21ac15939264a8157156acd199b432bb2.svg?v=1771221796\" alt=\"\" width=\"46\" height=\"46\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5553_default_small_100_100.jpg?v=1772198100\" alt=\"\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5554_default_small_100_100.jpg?v=1772198121\" alt=\"\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5574_default_small_100_100.jpg?v=1771255772\" alt=\"\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5484_default_small_100_100.jpg?v=1771221960\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"title title--s\"\u003eAFM Probe Specifications:\u003c\/h3\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003cdiv class=\"title title--xxs\"\u003eCoating\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eReflective Gold\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003cdiv class=\"title title--xxs\"\u003eAdditional Info\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eThe 160AC-FG AFM probes with carbon nanofibers at the end of the silicon AFM tips are designed for tapping mode AFM imaging of deep trenches. The typical fiber radius of curvature is 10 nm and the diameter is 50 nm at a height of 200 nm away from the apex.\u003c\/p\u003e\n\u003cp\u003eThe terahedral AFM tip is located precisely at the free end of the AFM cantilever. This allows the AFM tip to be positioned accurately over the area of interest on the sample surface.\u003c\/p\u003e\n\u003cp\u003eThe gold coating ensures high and stable laser reflectivity in air, vacuum and liquids. Please note that while the tetrahedral AFM tip and the AFM tip side of the AFM cantilever are gold coated, the diamond-like spike remains uncoated.\u003c\/p\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003ch4 class=\"title title--s\"\u003eAFM Tip:\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eSetback\u003c\/th\u003e\n\u003cth\u003eRadius\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eHigh-Aspect-Ratio\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e14 µm (12 - 16 µm)*\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e0 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e\u0026lt; 10 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003e* typical values\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003ch4 class=\"title title--s\"\u003eAFM Cantilever:\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCantilever\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eForce Const.\u003c\/th\u003e\n\u003cth\u003eRes. Freq.\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eThickness\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eHigh aspect ratio tapping mode AFM cantilever\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eBeam\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e26 N\/m\u003cspan class=\"table__content-light\"\u003e(8 - 57 N\/m)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e300 kHz\u003cspan class=\"table__content-light\"\u003e(200 - 400 kHz)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e160 µm\u003cspan class=\"table__content-light\"\u003e(150 - 170µm)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e40 µm\u003cspan class=\"table__content-light\"\u003e(38 - 42µm)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e4µm\u003cspan class=\"table__content-light\"\u003e(3.5 - 4.5 µm)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003e* typical values\u003c\/p\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"title title--s\"\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003e240AC-FG\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"subtitle\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eOPUS® High Aspect Ratio Soft Tapping Mode AFM Cantilever with Au Reflective Coating\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"46\" width=\"90\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/O70kHz_2.0Nonm.jpg?v=1771344765\"\u003e   \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/c54c843ac594213d1f1ff3f2f610646fbf6f7f2f.svg?v=1771221652\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/7060ef9f263008d5e11284098656c91c8e308635.svg?v=1771221709\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a780953b630073e7035e45e6bc31ed55fa166043.svg?v=1771221752\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/fe1a1af00894bcd3465a156e3506f99934c51c10.svg?v=1772198022\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a882079e57605157a188c26ef744164a1401f2ec.svg?v=1771246696\" alt=\"\" width=\"46\" height=\"46\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/8d216cc21ac15939264a8157156acd199b432bb2.svg?v=1771221796\" alt=\"\" width=\"46\" height=\"46\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5554_default_small_100_100.jpg?v=1772198121\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5553_default_small_100_100.jpg?v=1772198100\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5499_default_small_100_100.jpg?v=1771345297\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5500_default_small_100_100.jpg?v=1771345339\"\u003e\u003c\/p\u003e\n\u003ch3 class=\"title title--s\"\u003eAFM Probe Specifications:\u003c\/h3\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003cdiv class=\"title title--xxs\"\u003eCoating\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eReflective Gold\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003cdiv class=\"title title--xxs\"\u003eAdditional Info\u003c\/div\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp\u003eThe 240AC-FG AFM probes with carbon nanofibers at the end of the silicon AFM tips are designed for soft tapping mode AFM imaging of deep trenches. The typical fiber radius of curvature is 10 nm and the diameter is 50 nm at a height of 200 nm away from the apex.\u003c\/p\u003e\n\u003cp\u003eThe terahedral AFM tip is located precisely at the free end of the AFM cantilever. This allows the AFM tip to be positioned accurately over the area of interest on the sample surface.\u003c\/p\u003e\n\u003cp\u003eThe gold coating ensures high and stable laser reflectivity in air, vacuum and liquids. Please note that while the tetrahedral AFM tip and the AFM tip side of the AFM cantilever are gold coated, the diamond-like spike remains uncoated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003ch4 class=\"title title--s\"\u003eAFM Tip:\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eSetback\u003c\/th\u003e\n\u003cth\u003eRadius\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eHigh-Aspect-Ratio\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e14 µm (12 - 16 µm)*\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e0 µm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e\u0026lt; 10 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003e* typical values\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block\"\u003e\n\u003ch4 class=\"title title--s\"\u003eAFM Cantilever:\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCantilever\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eForce Const.\u003c\/th\u003e\n\u003cth\u003eRes. Freq.\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eThickness\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eHigh aspect ratio soft tapping mode AFM cantilever\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eBeam\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e2 N\/m\u003cspan class=\"table__content-light\"\u003e(0.6 - 3.9 N\/m)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e70 kHz\u003cspan class=\"table__content-light\"\u003e(45 - 90 kHz)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e240 µm\u003cspan class=\"table__content-light\"\u003e(230 - 250µm)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e40 µm\u003cspan class=\"table__content-light\"\u003e(38 - 42µm)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e2.6µm\u003cspan class=\"table__content-light\"\u003e(2.1 - 3.1 µm)*\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003e* typical values\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\" class=\"headline\"\u003e\n\u003cspan style=\"color: rgb(255, 128, 0);\" class=\"accent\"\u003eOPUS\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eAFM Probes:\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: rgb(255, 128, 0);\" class=\"accent\"\u003eO\u003c\/span\u003eptimized\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: rgb(255, 128, 0);\" class=\"accent\"\u003eP\u003c\/span\u003eositioning\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: rgb(255, 128, 0);\" class=\"accent\"\u003eU\u003c\/span\u003epon\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: rgb(255, 128, 0);\" class=\"accent\"\u003eS\u003c\/span\u003eample\u003c\/h4\u003e\n\u003ch2 style=\"text-align: center;\" class=\"banner-link__title\"\u003eOlympus replacement AFM probes\u003c\/h2\u003e\n\u003cdiv class=\"text\"\u003e\n\u003cp style=\"text-align: center;\"\u003eIn September 2022 Olympus®* Corp. decided to discontinue all their Olympus®* AFM probes. OPUS AFM tips are identical to Olympus®* AFM tips in form, fit and function.\u003c\/p\u003e\n\u003ch6 style=\"text-align: center;\"\u003e\u003cem\u003e*Olympus® is a trademark of Olympus Corporation\u003c\/em\u003e\u003c\/h6\u003e\n\u003c\/div\u003e","brand":"MikroMasch","offers":[{"title":"OPUS® High Aspect Ratio Standard Tapping Mode AFM Cantilever with Au Reflective Coating, pkg\/5 (Unit: each)","offer_id":56069927207238,"sku":"160AC-FG-5","price":6179.25,"currency_code":"RON","in_stock":true},{"title":"OPUS® High Aspect Ratio Soft Tapping Mode AFM Cantilever with Au Reflective Coating, pkg\/5 (Unit: each)","offer_id":56071137722694,"sku":"240AC-FG-5","price":6179.25,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/thumb_5553_default_small_100_100.jpg?v=1772198100","url":"https:\/\/allemee.com\/products\/opus-carbon-nanofiber-afm-tips","provider":"AllEm","version":"1.0","type":"link"}