{"product_id":"high-resolution-afm-probes","title":"High Resolution AFM Probes","description":"\u003ch2 class=\"Polaris-Header-Title\" tabindex=\"-1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/MikroMasch-Logo.svg?v=1768988367\"\u003e\u003c\/h2\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003ciframe width=\"1920\" height=\"1080\" src=\"https:\/\/www.youtube.com\/embed\/tBaQLC0D6DA\" title=\"MikroMasch HQ Line High Resolution AFM Probes\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"402\" width=\"416\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d9fe3ab77ff49cdb324489f31caaa83c19a8f204.jpg?v=1769671627\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical spike radius\u003c\/strong\u003e\u003cbr\u003e1nm\u003cbr\u003e\u003cstrong\u003eSpike height\u003c\/strong\u003e\u003cbr\u003e100-200nm\u003cbr\u003e\u003cstrong\u003eTotal AFM tip height\u003c\/strong\u003e\u003cbr\u003e12-18µm\u003cbr\u003e\u003cstrong\u003eAFM probe material\u003c\/strong\u003e\u003cbr\u003en-type silicon\u003cbr\u003e\u003cstrong\u003eAFM probe bulk resistivity\u003c\/strong\u003e\u003cbr\u003e0.01-0.025 Ohm·cm\u003cbr\u003e\u003cstrong\u003eAFM probe coating\u003c\/strong\u003e\u003cbr\u003eGold\u003c\/p\u003e\n\u003cp\u003eThe Hi’Res-C AFM probes have a diamond-like spike on the apex of the silicon AFM tip. The sharpness of the spike determines the resolution. The high-resolution AFM probes are recommended for scanning small areas below 250nm at 512 sampling points. Lateral resolution below 1nm is attainable.\u003c\/p\u003e\n\u003cp\u003eThe probes feature an overall gold coating for improved laser reflectivity and chemical intertness. The diamond-like spike is not coated!\u003c\/p\u003e\n\u003ch4\u003e1 AFM Cantilever Series\u003c\/h4\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/www.spmtips.com\/uploads\/media\/default\/0001\/06\/9ac28078763ea21bc3f6e8f72a447c574870fd04.jpeg\" alt=\"\" width=\"500\" height=\"422\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"scrollable-content\"\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"2\"\u003e\u003cstrong\u003eAFM Cantilever\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003e\u003cstrong\u003eResonance Frequency, kHz\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003e\u003cstrong\u003eForce Constant, N\/m\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emin\u003c\/th\u003e\n\u003cth\u003etypical\u003c\/th\u003e\n\u003cth\u003emax\u003c\/th\u003e\n\u003cth\u003emin\u003c\/th\u003e\n\u003cth\u003etypical\u003c\/th\u003e\n\u003cth\u003emax\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\"\u003e14 series\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e160\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e1.8\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\"\u003e15 series\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e325\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\"\u003e18 series\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e75\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e1.2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"1\"\u003e19 series\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e65\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cbr\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eApplication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAFM has become the tool of choice for non-destructive surface measurements with molecular and sub-molecular resolution. However, the resolution and accuracy of the technique is limited by the size and shape of the AFM tip. In order to increase resolution, it is necessary to decrease both the AFM tip size and the AFM tip-sample interaction force\u003c\/p\u003e\n\u003cp\u003eThe development of the line of Hi’Res-C AFM probes has overcome these obstacles and made higher resolution, sub-nanometer imaging possible. The Hi’Res AFM probes allow for more accurate measurement of extremely narrow features such as pores, trenches, and sharp edges, along with accurate measurement of sub-nanometer surface roughness.\u003c\/p\u003e\n\u003cp\u003eIn addition, these AFM probes are also suitable for imaging soft, fragile and near-liquid samples as the AFM tip-sample attraction force is significantly reduced due to the unsurpassed sub-nanometer AFM tip radius.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/www.spmtips.com\/uploads\/gallery\/conventional-silicon-afm-probe-in-tapping-mode-20121028041045.jpg\" alt=\"Standard silicon AFM probe in tapping mode. AFM tip radius ~10nm.\" width=\"200\"\u003e\n\u003cfigcaption\u003e\u003cem\u003eStandard silicon AFM probe in tapping mode. AFM tip radius ~10nm.\u003c\/em\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/www.spmtips.com\/uploads\/gallery\/Hi-RES-afm-probe-in-tapping-mode-20121028041045.jpg\" alt=\"Hi’Res probe in Tapping mode. Individual molecules are resolved. Tip radius Rtip ~1nm.\"\u003e\n\u003cfigcaption\u003e\u003cem\u003eHi’Res probe in Tapping mode. Individual molecules are resolved. Tip radius Rtip ~1nm.\u003c\/em\u003e\u003cbr\u003e\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003cp class=\"Stext\"\u003e\u003cem\u003eRoutine height images of carbosilane dendrimers (9th generation) in a dense film obtained using Bruker Multimode Nanoscope IIIa AFM. Scan size 150nm. Diameter of dendrimer molecules is 9nm. Images courtesy of S.S. Sheiko (University of North Caroline at Chapel Hill) and D.A. Ivanov (Free University of Brussels). Dendrimers courtesy of A. M. Muzafarov (ISPM RAS, Moscow.)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eHi'Res-C AFM probes suffer less contamination than silicon SPM probes and allow obtaining many high-resolution scans when proper care is taken during use. Due to the small AFM tip curvature radius, the AFM tip-sample attraction force is minimized.\u003cbr\u003e\u003cbr\u003eThe advantages of the Hi'Res-C AFM probes are noticeable when scanning smaller areas (\u0026lt;250nm) and flat samples. On larger images, the resolution is similar to that of general purpose AFM probes. The Hi'Res-C AFM probes are not suitable for corrugated samples.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2 class=\"title title--sxl\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHi'Res-C15\/Cr-Au\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eHigh Resolution, Tapping Mode AFM Probe\u003c\/h3\u003e\n\u003cdiv class=\"content-block sbo-xs\"\u003e\n\u003cdiv class=\"text text--ul text--small\"\u003e\n\u003cp\u003eThe high-resolution AFM probes of the Hi'Res-C series feature a hydrophobic diamond-like spike at the apex of the silicon etched AFM tip.\u003c\/p\u003e\n\u003cp\u003eAFM probes of the HQ:NSC19 series combine relatively high resonance frequency and low force constant, which makes them suitable for imaging soft and fragile surfaces at relatively high speeds in Soft tapping mode. They are compatible with Bruker ScanAsyst® PeakForce Tapping™*.\u003c\/p\u003e\n\u003cp\u003eThe HQ AFM probes offer high consistency of the AFM tip radius, the AFM cantilever reflectivity and the quality factor.\u003c\/p\u003e\n\u003cp\u003eThe overall 30 nm Au coating with 20 nm Cr sublayer is chemically inert. It also ehnances the laser reflectivity of the AFM cantilever in air and liquids. The coating does not cover the spike.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"text text--small\"\u003e\n\u003cp\u003eReflective Gold\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/325kHz_40Nonm.jpg?v=1768991895\" alt=\"\" width=\"82\" height=\"48\"\u003e   \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/62acfeecf2e7996a6e2c4069f522281ed51e7029.svg?v=1769671006\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/057b53dd4333abb1225a35499f36b1102fff8bcf.svg?v=1768991625\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/91c7299a13df894ca20f18d14e1e46197f6f5909.svg?v=1768991397\" alt=\"\" width=\"40\" height=\"41\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"389\" width=\"403\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d9fe3ab77ff49cdb324489f31caaa83c19a8f204.jpg?v=1769671627\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"235\" width=\"404\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/cfc56b0cf90962ff9060470bbfd365921d810e8a_d82640e8-cb64-44d7-94b2-26383bce96d0.jpg?v=1769078495\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e  \u003cimg height=\"187\" width=\"195\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/31d712aa7943efcfd738afe37e46d32700340a21.jpg?v=1769684975\"\u003e  \u003cimg height=\"187\" width=\"215\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/0586e07e00c72803fe4e6ed59c8ac42c5e91b481.jpg?v=1769685007\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eAFM Probe Specifications\u003c\/h3\u003e\n\u003cdiv class=\"content-block  sbo-x\"\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Tip\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eRadius\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eSupersharp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e15 µm (12 - 18 µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e\u0026lt; 1 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Cantilever\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCantilever\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eForce Const.\u003c\/th\u003e\n\u003cth\u003eRes. Freq.\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eThickness\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eCantilever A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eBeam\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e40 N\/m\u003cspan class=\"table__content-light\"\u003e(20 - 80 N\/m)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e325 kHz\u003cspan class=\"table__content-light\"\u003e(265 - 410 kHz)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e125 µm\u003cspan class=\"table__content-light\"\u003e(120 - 130µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e30 µm\u003cspan class=\"table__content-light\"\u003e(27 - 33µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e4 µm\u003cspan class=\"table__content-light\"\u003e(3.5 - 4.5 µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003eAll typical values\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv class=\"content-block sbo-xs\"\u003e\n\u003cdiv class=\"text text--ul text--small\"\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"text text--small\"\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003ch2 class=\"title title--sxl\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHi'Res-C18\/Cr-Au\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"align-right gray-text\"\u003eHigh Resolution, Soft Tapping Mode AFM Probe\u003c\/h3\u003e\n\u003cdiv class=\"content-block sbo-xs\"\u003e\n\u003cdiv class=\"text text--ul text--small\"\u003e\n\u003cp\u003eThe high-resolution AFM probes of the Hi'Res-C series feature a hydrophobic diamond-like spike at the apex of the silicon etched AFM tip.\u003c\/p\u003e\n\u003cp\u003eAFM probes of the HQ:NSC18 series series are suitable for soft tapping and Lift mode operation AFM, Force modulation mode and true topography imaging of soft samples in Soft tapping mode.\u003c\/p\u003e\n\u003cp\u003eThe HQ AFM probes offer high consistency of the AFM tip radius, the AFM cantilever reflectivity and the quality factor.\u003c\/p\u003e\n\u003cp\u003eThe overall 30 nm Au coating with 20 nm Cr sublayer is chemically inert. It also ehnances the laser reflectivity of the AFM cantilever in air and liquids. The coating does not cover the spike.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"text text--small\"\u003e\n\u003cp\u003eReflective Gold\u003c\/p\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"text text--small\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"44\" width=\"103\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/75kHz_2.8Nonm.jpg?v=1769590988\"\u003e   \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/62acfeecf2e7996a6e2c4069f522281ed51e7029.svg?v=1769671006\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/057b53dd4333abb1225a35499f36b1102fff8bcf.svg?v=1768991625\"\u003e \u003cimg height=\"41\" width=\"40\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/60c9f1ed8036d365045dc7162a0fcd022aaefd42.svg?v=1769066989\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"389\" width=\"403\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d9fe3ab77ff49cdb324489f31caaa83c19a8f204.jpg?v=1769671627\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"235\" width=\"404\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/cfc56b0cf90962ff9060470bbfd365921d810e8a_d82640e8-cb64-44d7-94b2-26383bce96d0.jpg?v=1769078495\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e  \u003cimg height=\"204\" width=\"223\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/46ea892e382b1ef98e15f0ceac995a182a42ae8a_ecd1e41c-c67b-4ad6-a11a-8430a1104ae0.jpg?v=1769684199\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eAFM Probe Specifications\u003c\/h3\u003e\n\u003cdiv class=\"content-block  sbo-x\"\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Tip\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eRadius\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eSupersharp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e15 µm (12 - 18 µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e\u0026lt; 1 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Cantilever\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCantilever\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eForce Const.\u003c\/th\u003e\n\u003cth\u003eRes. Freq.\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eThickness\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eCantilever A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eBeam\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e2.8 N\/m\u003cspan class=\"table__content-light\"\u003e(1.2 - 5.5 N\/m)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e75 kHz\u003cspan class=\"table__content-light\"\u003e(60 - 90 kHz)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e225 µm\u003cspan class=\"table__content-light\"\u003e(220 - 230µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e27.5 µm\u003cspan class=\"table__content-light\"\u003e(24.5 - 30.5µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e3 µm\u003cspan class=\"table__content-light\"\u003e(2.5 - 3.5 µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003eAll typical values\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2 class=\"title title--sxl\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHi'Res-C19\/Cr-Au\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eHigh Resolution, Soft Tapping Mode AFM Probe, Low Force Constant\u003c\/h3\u003e\n\u003cp\u003eThe high-resolution AFM probes of the Hi'Res-C series feature a hydrophobic diamond-like spike at the apex of the silicon etched AFM tip.\u003c\/p\u003e\n\u003cp\u003eAFM probes of the HQ:NSC19 series combine relatively high resonance frequency and low force constant, which makes them suitable for imaging soft and fragile surfaces at relatively high speeds in Soft tapping mode. They are compatible with Bruker ScanAsyst® PeakForce Tapping™*.\u003c\/p\u003e\n\u003cp\u003eThe HQ AFM probes offer high consistency of the AFM tip radius, the AFM cantilever reflectivity and the quality factor.\u003c\/p\u003e\n\u003cp\u003eThe overall 30 nm Au coating with 20 nm Cr sublayer is chemically inert. It also ehnances the laser reflectivity of the AFM cantilever in air and liquids. The coating does not cover the spike.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"text text--small\"\u003e\n\u003cp\u003eReflective Gold\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/325kHz_40Nonm.jpg?v=1768991895\" alt=\"\" width=\"82\" height=\"48\"\u003e   \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/62acfeecf2e7996a6e2c4069f522281ed51e7029.svg?v=1769671006\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/057b53dd4333abb1225a35499f36b1102fff8bcf.svg?v=1768991625\"\u003e \u003cimg height=\"41\" width=\"40\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/60c9f1ed8036d365045dc7162a0fcd022aaefd42.svg?v=1769066989\"\u003e \u003cimg height=\"40\" width=\"40\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/227785e50b21dfbbd43641f4b0d77e7809985b92.svg?v=1769592600\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"389\" width=\"403\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d9fe3ab77ff49cdb324489f31caaa83c19a8f204.jpg?v=1769671627\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"235\" width=\"404\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/cfc56b0cf90962ff9060470bbfd365921d810e8a_d82640e8-cb64-44d7-94b2-26383bce96d0.jpg?v=1769078495\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg height=\"204\" width=\"226\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/c3025521faeb8291428672c6faee1ae2119db7f1.jpg?v=1769592770\"\u003e  \u003cimg height=\"204\" width=\"223\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/46ea892e382b1ef98e15f0ceac995a182a42ae8a_ecd1e41c-c67b-4ad6-a11a-8430a1104ae0.jpg?v=1769684199\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"title title--s title--s-secondary\"\u003eAFM Probe Specifications\u003c\/h3\u003e\n\u003cdiv class=\"content-block  sbo-x\"\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Tip\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003cth\u003eRadius\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eSupersharp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e15 µm (12 - 18 µm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003e\u0026lt; 1 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content-block sbo-x\"\u003e\n\u003cdiv class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch4 class=\"title title--xsm-secondary sbo-xxxs-constant\"\u003eAFM Cantilever\u003c\/h4\u003e\n\u003cdiv class=\"table-cont\"\u003e\n\u003ctable class=\"table table--small table--responsive center\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCantilever\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth\u003eForce Const.\u003c\/th\u003e\n\u003cth\u003eRes. Freq.\u003c\/th\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003cth\u003eThickness\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"table__content primary\"\u003eCantilever A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003eBeam\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e0.5 N\/m\u003cspan class=\"table__content-light\"\u003e(0.05 - 2.3 N\/m)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e65 kHz\u003cspan class=\"table__content-light\"\u003e(25 - 120 kHz)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e125 µm\u003cspan class=\"table__content-light\"\u003e(120 - 130µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e22.5 µm\u003cspan class=\"table__content-light\"\u003e(19.5 - 25.5µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"table__content\"\u003e1 µm\u003cspan class=\"table__content-light\"\u003e(0.5 - 1.5 µm)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"align-right gray-text\"\u003eAll typical values\u003c\/p\u003e\n\u003c\/div\u003e","brand":"MikroMasch","offers":[{"title":"High Resolution, Tapping Mode AFM Probe, pkg\/5 (Unit: each)","offer_id":55894712189254,"sku":"HiRes-C15\/Cr-Au-5","price":2780.66,"currency_code":"RON","in_stock":true},{"title":"High Resolution, Soft Tapping Mode AFM Probe pkg\/5 (Unit: each)","offer_id":55894759637318,"sku":"HiRes-C18\/Cr-Au-5","price":2780.66,"currency_code":"RON","in_stock":true},{"title":"High Resolution, Soft Tapping Mode AFM Probe, Low Constant Force pkg\/5 (Unit: each)","offer_id":55894254616902,"sku":"HiRes-C19\/Cr-Au-5","price":2780.66,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/0586e07e00c72803fe4e6ed59c8ac42c5e91b481.jpg?v=1770894945","url":"https:\/\/allemee.com\/products\/high-resolution-afm-probes","provider":"AllEm","version":"1.0","type":"link"}