{"product_id":"force-modulation-afm-probes","title":"Force Modulation AFM Probes","description":"\u003cp\u003e\u003ca href=\"https:\/\/www.budgetsensors.com\/\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/BS-logo.png?v=1779784298\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"BudgetSensors Multi75 Series AFM Probes\" src=\"https:\/\/www.youtube.com\/embed\/bqXzvN1o2DA\" height=\"524\" width=\"917\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eMulti75-G\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eForce Modulation AFM Probe\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eAFM Probe Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"techData tips clearfix\"\u003e\n\u003ch3\u003eAFM Tip\u003c\/h3\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eShape:\u003c\/strong\u003e Rotated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17 µm \u003cspan class=\"light\"\u003e(15 - 19 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eSetback:\u003c\/strong\u003e 15 µm \u003cspan class=\"light\"\u003e(10 - 20 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eRadius:\u003c\/strong\u003e \u0026lt; 10 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-4\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHalf Cone Angle:\u003c\/strong\u003e 20°-25° along cantilever axis, 25°-30° from side, 10° at the apex\u003c\/div\u003e\n\u003cdiv class=\"spec\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cantilevers\"\u003e\n\u003ch3\u003eAFM Cantilever\u003c\/h3\u003e\n\u003cdiv xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" id=\"cantilever1\" class=\"techData  col-lg-12 pl0 clearfix\"\u003e\n\u003cdiv class=\"cantilever\"\u003eCantilever A\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eShape:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeam\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eForce Constant:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  3 N\/m (1 - 7 N\/m)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eResonance Frequency:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 75 kHz (60 - 90 kHz)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eLength:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 225 µm (215 - 235 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eWidth:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 28 µm (23 - 33 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eThickness:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  3 µm (2 - 4 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e* typical range\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"probe_coating clearfix\"\u003e\n\u003ch3\u003eCoating\u003c\/h3\u003e\n\u003cp\u003eUncoated\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAlignment Grooves\u003c\/h3\u003e\n\u003cp\u003eThis product features alignment grooves on the back side of the holder chip.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/f2e52215a579466143e29f8a9c6ee6484a59e3d5.png?v=1779951258\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/c7c808a00cfeac9dfe6ef3bb0d874da71333079c.png?v=1779951235\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d2b21d245ae46545b9615e67bb20d16afd5574de_941a17bb-f67f-4143-b863-4313660843ba.png?v=1779951277\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAdditional Info\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMonolithic silicon AFM probe for force modulation and pulsed force mode (PFM).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe rotated AFM tip allows for more symmetric representation of high sample features. The consistent AFM tip radius ensures good resolution and reproducibility.\u003c\/p\u003e\n\u003cp\u003eThe AFM holder chip fits most commercial AFM systems as it is industry standard size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor measurements in liquids please use the back side gold coated\u003cspan\u003e \u003c\/span\u003eMulti75GD-G\u003cspan\u003e \u003c\/span\u003eor the overall gold coated\u003cspan\u003e \u003c\/span\u003eMulti75GB-G!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsistent high quality at a lower price!\u003c\/p\u003e\n\u003chr\u003e\u003chr\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eMulti75Al-G\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eForce Modulation AFM Probe with Aluminum Reflective Coating\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eAFM Probe Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"techData tips clearfix\"\u003e\n\u003ch3\u003eAFM Tip\u003c\/h3\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eShape:\u003c\/strong\u003e Rotated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17 µm \u003cspan class=\"light\"\u003e(15 - 19 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eSetback:\u003c\/strong\u003e 15 µm \u003cspan class=\"light\"\u003e(10 - 20 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eRadius:\u003c\/strong\u003e \u0026lt; 10 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-4\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHalf Cone Angle:\u003c\/strong\u003e 20°-25° along cantilever axis, 25°-30° from side, 10° at the apex\u003c\/div\u003e\n\u003cdiv class=\"spec\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cantilevers\"\u003e\n\u003ch3\u003eAFM Cantilever\u003c\/h3\u003e\n\u003cdiv xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" id=\"cantilever1\" class=\"techData  col-lg-12 pl0 clearfix\"\u003e\n\u003cdiv class=\"cantilever\"\u003eCantilever A\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eShape:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeam\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eForce Constant:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  3 N\/m (1 - 7 N\/m)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eResonance Frequency:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 75 kHz (60 - 90 kHz)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eLength:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 225 µm (215 - 235 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eWidth:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 28 µm (23 - 33 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eThickness:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  3 µm (2 - 4 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e* typical range\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"probe_coating clearfix\"\u003e\n\u003ch3\u003eCoating\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eAluminium reflex coating on detector side of the cantilever, 30 nm thick\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAlignment Grooves\u003c\/h3\u003e\n\u003cp\u003eThis product features alignment grooves on the back side of the holder chip.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/f2e52215a579466143e29f8a9c6ee6484a59e3d5.png?v=1779951258\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/c7c808a00cfeac9dfe6ef3bb0d874da71333079c.png?v=1779951235\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d2b21d245ae46545b9615e67bb20d16afd5574de_941a17bb-f67f-4143-b863-4313660843ba.png?v=1779951277\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAdditional Info\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMonolithic silicon AFM probe for force modulation and pulsed force mode (PFM).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe rotated AFM tip allows for more symmetric representation of high sample features. The consistent AFM tip radius ensures good resolution and reproducibility.\u003c\/p\u003e\n\u003cp\u003eThe AFM holder chip fits most commercial AFM systems as it is industry standard size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor measurements in liquids please use the back side gold coated\u003cspan\u003e \u003c\/span\u003eMulti75GD-G\u003cspan\u003e \u003c\/span\u003eor the overall gold coated\u003cspan\u003e \u003c\/span\u003eMulti75GB-G!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsistent high quality at a lower price!\u003c\/p\u003e\n\u003chr\u003e\u003chr\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe title=\"BudgetSensors Multi75 Series AFM Probes\" src=\"https:\/\/www.youtube.com\/embed\/bqXzvN1o2DA\" height=\"524\" width=\"917\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe width=\"917\" height=\"524\" src=\"https:\/\/www.youtube.com\/embed\/ymey_oRf9n0\" title=\"BudgetSensors Gold Series AFM Probes\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eMulti75GD-G\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan class=\"sub-heading\"\u003eForce Modulation AFM Probe with Gold Reflective Coating\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eAFM Probe Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"techData tips clearfix\"\u003e\n\u003ch3\u003eAFM Tip\u003c\/h3\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eShape:\u003c\/strong\u003e Rotated\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17 µm \u003cspan class=\"light\"\u003e(15 - 19 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eSetback:\u003c\/strong\u003e 15 µm \u003cspan class=\"light\"\u003e(10 - 20 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-2\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eRadius:\u003c\/strong\u003e \u0026lt; 10 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-lg-4\"\u003e\n\u003cdiv class=\"headline\"\u003e\n\u003cstrong\u003eHalf Cone Angle:\u003c\/strong\u003e 20°-25° along cantilever axis, 25°-30° from side, 10° at the apex\u003c\/div\u003e\n\u003cdiv class=\"spec\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cantilevers\"\u003e\n\u003ch3\u003eAFM Cantilever\u003c\/h3\u003e\n\u003cdiv xmlns=\"http:\/\/www.w3.org\/1999\/xhtml\" id=\"cantilever1\" class=\"techData  col-lg-12 pl0 clearfix\"\u003e\n\u003cdiv class=\"cantilever\"\u003eCantilever A\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eShape:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeam\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eForce Constant:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  3 N\/m (1 - 7 N\/m)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eResonance Frequency:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 75 kHz (60 - 90 kHz)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eLength:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 225 µm (215 - 235 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003clabel\u003eWidth:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e 28 µm (23 - 33 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dark\"\u003e\n\u003cstrong\u003e\u003clabel\u003eThickness:\u003c\/label\u003e\u003c\/strong\u003e\u003cspan\u003e  3 µm (2 - 4 µm)*\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e* typical range\u003c\/div\u003e\n\u003cdiv class=\"light\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"probe_coating clearfix\"\u003e\n\u003ch3\u003eCoating\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eGold coating on detector side of the cantilever, 70 nm thick\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eAlignment Grooves\u003c\/h3\u003e\n\u003cp\u003eThis product features alignment grooves on the back side of the holder chip.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/c7c808a00cfeac9dfe6ef3bb0d874da71333079c.png?v=1779951235\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/f2e52215a579466143e29f8a9c6ee6484a59e3d5.png?v=1779951258\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/d2b21d245ae46545b9615e67bb20d16afd5574de_941a17bb-f67f-4143-b863-4313660843ba.png?v=1779951277\"\u003e\u003c\/p\u003e\n\u003ch3\u003eAdditional Info\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMonolithic silicon AFM probe for force modulation and pulsed force mode (PFM) in air and liquids.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe rotated AFM tip allows for more symmetric representation of high sample features. The consistent AFM tip radius ensures good resolution and reproducibility.\u003c\/p\u003e\n\u003cp\u003eThe AFM holder chip fits most commercial AFM systems as it is industry standard size.\u003c\/p\u003e\n\u003cp\u003eConsistent high quality at a lower price!\u003c\/p\u003e","brand":"BudgetSensors","offers":[{"title":"Multi75-G Force Modulation AFM Probe, uncoated, alignment grooves (Unit: pkg\/10)","offer_id":56677054611782,"sku":"Multi75-G-10","price":1101.44,"currency_code":"RON","in_stock":true},{"title":"Multi75-G Force Modulation AFM Probe, uncoated, alignment grooves (Unit: pkg\/50)","offer_id":56677054644550,"sku":"Multi75-G-50","price":4829.38,"currency_code":"RON","in_stock":true},{"title":"Multi75-G Force Modulation AFM Probe, uncoated, alignment grooves (Unit: pkg\/380)","offer_id":56677054677318,"sku":"Multi75-G-380","price":25417.8,"currency_code":"RON","in_stock":true},{"title":"Multi75Al Force Modulation AFM Probe, Al reflex coating, alignment grooves (Unit: pkg\/10)","offer_id":56677054710086,"sku":"Multi75Al-G-10","price":1157.92,"currency_code":"RON","in_stock":true},{"title":"Multi75Al Force Modulation AFM Probe, Al reflex coating, alignment grooves (Unit: pkg\/50)","offer_id":56677054742854,"sku":"Multi75Al-G-50","price":5055.32,"currency_code":"RON","in_stock":true},{"title":"Multi75Al Force Modulation AFM Probe, Al reflex coating, alignment grooves (Unit: pkg\/380)","offer_id":56677054775622,"sku":"Multi75Al-G-380","price":25417.8,"currency_code":"RON","in_stock":true},{"title":"Multi75GD-G Force Modulation AFM Probe, Au reflex coating, alignment grooves (Unit: pkg\/10)","offer_id":56677054808390,"sku":"Multi75GD-G-10","price":1468.58,"currency_code":"RON","in_stock":true},{"title":"Multi75GD-G Force Modulation AFM Probe, Au reflex coating, alignment grooves (Unit: pkg\/50)","offer_id":56677054841158,"sku":"Multi75GD-G-50","price":6100.27,"currency_code":"RON","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0909\/0452\/7174\/files\/a19788d7be80dcdfd27d5fd7590eee5f5ee3bde4.png?v=1779898973","url":"https:\/\/allemee.com\/products\/force-modulation-afm-probes","provider":"AllEm","version":"1.0","type":"link"}